Name of measuring instrument Parameter Category/ Typical model Name, Code of calibration regulation Measuring range Best Measurement Capability Expanded As An uncertainty
24 SS7 Tester E1interface frequency QSZ-7 TMC-XZ-001

SS7 Tester Specification of calibration
2M 2*10-7
Output pulse shape Amplitude 0.01~0.03V,
Output jitter 0.01UIpp
Input jitter tolerance 3.5%
40 Network performance Analyzer Electrical Interface Test Allow loss Network performance Analyzer SmartBits 2000 TMCOS006 Electrical/Optical interface parameter of Digital Telecommunication calibration operate criterion 6~12.7dB  
The return loss at the input port Frequency 51.2kHz ~240MHz 1dB
Rate offset at input 大于± 50×10-6  
Maximum peak-to-peak jitter at an input port Jitter frequency 20Hz ~20MHz Jitter amplitude 0~20UIpp 3.5%
Pulse shape at output HDB3、CMI Amplitude 0.01~0.03V Time Interval 0.1~1ns
Maximum peak-to-peak jitter at an output port Jitter amplitude 0~10UIpp 5.8%
Frequency (or Rate) 2M~ 622M 2×10-7
40 Network performance Analyzer (continue) Optical Interface Test Optical wavelength Network performance Analyzer SmartBits 2000 TMCOS006 Electrical/Optical interface parameter of Digital Telecommunication calibration operate criterion 800~1600nm 1nm
Maximum spectrum width
Average optical power -80dBm~+3dBm 2%
Minimum sensitivity
Maximum bit rate offset of optical signal at input 2M~ 622M jitter:±5%×measure  value±0.1
40 Network performance Analyzer (Continue) Optical Interface Test Maximum peak-to-peak jitter at an input port Network performance Analyzer SmartBits 2000 TMCOS006 Electrical/Optical interface parameter of Digital Telecommunication calibration operate criterion 2M~ 622M jitter:±5%×measure  value±0.1
Maximum peak-to-peak jitter at an output port
Minimum extinction ratio 155M~ 622M 622M~ 2.5G 1% 0.8%
Sys mask
Rise time
Faill time
jitter
Transfer performance: All parameters 1.1.             TMC-XZ-01-010 1.2.             Network performance Analyzer calibration operate criterion 10/ 100M interface 100ns
Coding Function: All parameters 10/100Methernet  
52 Protocol Analyzer Electrical Interface Test Allow loss Protocol Analyzer J 2300C、interwatch 95000、AX/4000、RADCOM series Protocol Analyzer calibration operate criterion TMC-XZ-01-019 6~12.7dB    
Minimum signal-to-interference ratio 18~20dB    
The return loss at the input port Frequency 51.2kHz ~240MHz 1dB  
Rate offset at input 大于± 50×10-6    
Maximum peak-to-peak jitter at an input port Jitter frequency 20Hz ~20MHz Jitter amplitude 0~20UIpp 3.5%  
Pulse shape at output HDB3、CMI Amplitude 0.01~0.03V Time Interval 0.1~1ns  
Maximum peak-to-peak jitter at an output port Jitter amplitude 0~10UIpp 5.8%  
Frequency (or Rate) 2M~ 622M 2×10-7  
52 Protocol Analyzer (cont.) Optical Interface Test Optical wavelength Protocol Analyzer SmartBits 2000 Protocol Analyzer calibration operate criterion TMC-XZ-01-019 800~1600nm 1nm  
Maximum spectrum width  
Average optical power -80dBm~+3dBm 2%  
Minimum sensitivity  
Maximum bit rate offset of optical signal at input 2M~ 622M 5.8%  
Maximum peak-to-peak jitter at an input port 2M~ 622M 5.8%  
Maximum peak-to-peak jitter at an output port  
52 Protocol Analyzer (cont.) Optical Interface Test Minimum extinction ratio Protocol Analyzer SmartBits 2000 Protocol Analyzer calibration operate criterion TMC-XZ-01-019 155M~ 622M 622M~ 2.5G 1% 0.8%  
Sys mask  
Rise time  
Faill time  
jitter  
25 ISDN tester timing extraction jitter(TE) PT500, CoBRA, 830e, sunrise, LM2000, HPJ2302B TMC-XZ-002-2002 ISDN tester calibration criterions 0~0.5UI 0.4%UI
Total phase deviation input to output(TE) ±1UI 0.6%UI
output jitter(NT) 0~0.5UI 0.4%UI
Transmitter output impedance 15W~25W
Receiver input impedance 100W~5kW 2kHz≤f≤300kHz,<5%test value; f>300kHz, <7% test value
peak current 0.1mA~1mA 30μA,i≤60μA;5 test value,i>600μA
output pulse shape –30mV~+210mV,5.6W; –75mV~+825mV,50W; –75mV~+2025mV,400W 15mV,5.6Ω&50Ω; 20mV,400Ω
pulse unbalance 0%~±10% area,2.5% amplitude,2%
unbalance 38dB~78dB 0.5dB
25(continue) ISDN tester impedance & return loss PT500, CoBRA, 830e, sunrise, LM2000, HPJ2302B 1.3.             TMC-XZ-002-2002 ISDN tester calibration criterions 0dB~25dB 5kHz~200kHz,ar=10dB~25dB, 0.5dB 1kHz~200kHz,ar=0dB~35dB, 1.5dB
pulse shape 400MHz 1.25%
longitudinal unbalance 20dB~70dB 2kHz~50kHz,as=20dB~55dB, 0.5dB 2kHz~50kHz,as=55dB~70dB, 1.5dB 0.5kHz~200kHz,as=20dB~55dB, 1.5dB 0.2kHz~0.5kHz,as=20dB~45dB, 3dB 200kHz~1MHz,as=20dB~45dB, 1.5dB
longitudinal output voltage -40dBV~-90dBV 2.5kHz~170kHz,agl=-40dBV~-50dBV, 0.5dBV 170kHz~300kHz,agl=-50dBV~-80dBV, 1.0dBV
power density frequency range:2.5kHz~1MHz;lever test range:-20dBm/Hz~-86dBm/Hz 1dB
25(continue) ISDN tester total power PT500, CoBRA, 830e, sunrise, LM2000, HPJ2302B 1.4.             TMC-XZ-002-2002 ISDN tester calibration criterions frequency range:100Hz~80kHz;lever test range:10dBm~15dBm 0.5dB
transmitter linearity -128dB~-20dB 50Hz
E1:bit rate 0~16UIpp 0.1×10-6
E1:pulse shape 400MHz 1.25%
E1:output jitter 0~16UIpp 0.1×10-6
E1:input jitter tolerance 0~16UIpp 0.1×10-6
E1:input bit rate tolerance 0~16UIpp 0.1×10-6
E1:input attenuation tolerance 0~16UIpp 0.1×10-6
E1:return loss 50Hz~25MHz 0.2dB
E1:input interfere immunity characteristics 0~16UIpp 0.1×10-6