Level、Attenuator

level generator, Digital Multi-meter, Multifunction Calibrator, Cable Tester, Earth Resistance Meter, level meter, attenuator, etc

Name of measuring instrument Parameter Category/ Typical model Name, Code of calibration regulation Measuring range Best Measurement Capability Expanded As An uncertainty
11 level generator frequency level generator JJG374-97 verification regulation for level generator 50Hz~36MHz 75Ω 150Ω 600Ω 0.1~1Hz
zero level 0.03dB
output level 0.1 dB
Level indicator 0.1 dB
output harmonic wave distortion 1~2dB
23 Digital Multimeter Multifunction Calibrator
  DC Voltage 5100B   9200A JJG445-86 Verification Regulation of Precise AC Voltage Calibration Source JJG410-94 Verification Regulation of DC Standard Voltage  Source JJG166-93 1.1.          Verification  Regulation of D. C. Resistors 0~1000V 2×10-5
AC Voltage 100Hz~1MHz 0~750V 2×10-4
DC Current 0~ 1A 3×10-4
AC Current 100Hz~1kHz 0~ 1A 3×10-3
Ohms 10Ω~100MΩ 6×10-6
Digital Multimeter
DC Voltage 3458A 8840A 34401A JJG315-83 1.2.          Verification Regulation of DC Digital Voltmeter 0~1000V 6×10-6
AC Voltage JJG(Space Light)34-1999 Verification Regulation 1.3.          For AC Digital Voltmeter 100Hz~1MHz 0~750V 7×10-5
23(continue) Digital Multimeter DC Current 3458A 8840A 34401A JJG598-89 Verification Regulation of DC Digital Ampere meter

0~ 1A 2×10-4
AC Current JJG(Space Light)35-1999 Verification Regulation For AC Digital Current meter 100Hz~5kHz 0~ 1A 6×10-4
Ohms JJG724-91 1.4.          Verification Regulation of DC Digital Ohm meter 0.1Ω~    100MΩ 6×10-6
26 Cable Tester Attenuation DSP4000 TMC-XZ-003 Cable Tester Calibration Criterions 1MHz ~ 250MHz 4.26%
NEXT 1MHz ~ 250MHz 4.26%
FEXT 1MHz ~ 250MHz 4.26%
Return Loss 1MHz ~ 250MHz 4.26%
Impedence 1MHz ~ 250MHz 4.26%
Value of Power 0~-50dBm 2%
Characteristic of Optical Source 800~1600nm 0~-50dBm 0.1nm 2%
39 Earth Resistance Meter  Resistance DV Resistor      ZX54 1.5.             JJG366-1986 Verification Regulation of Earth Resistance Meter 0.01Ω~100kΩ 0.01%
DC Voltage Multimeter 3458A 0~500V 5×10-4
AC Voltage 10Hz~1kHz 0~300V 6×10-3
12 level meter ( selective / wideband) frequency level meter (selective/ wideband) JJG777-92 verification regulation for selective level meter JJG(YD)027-94 1.6.            verification regulation for wideband level meter 50Hz~36MHz 75Ω 150Ω 600Ω 0.1~1Hz
zero level 0.03dB
Level indicator 0.1 dB
input level 0.1dB
13 attenuator attennua tion balance attenuator JJG028-94 verification regulation for balance variety attenuator 10kHz~14MHz 150Ω 50Hz~620kHz 600Ω 0.01~0.07dB
imbalance attenuator 1.7.             JJG419-86 1.8.          Verification regulation for  telecom carrier frequency variety attenuator 10kHz~36MHz 75Ω 0.01~0.07dB

 


Contact us | Map | Links
Copyright© Telecommunication Metrology Center of MII  Design:superdesign
Address:NO.52 Huayuan Bei Road Haidian Disitrict Beijing,PRC 100083 Telephone:010-62301383/62302041
Fax:010-62304104  E-mail:cal@catr.com.cn